ENVIRONMENTAL TESTS STANDS

RI-154
Description

The Environmental Testing Laboratory has the infrastructure to test the finished product in terms of mechanical and climatic testing after the production stage. The scope of testing processes includes resistance and strength to mechanical and climatic stresses tests and functional tests of products.

Main technical characteristics

IMV SHAKER I250/SA4M-CE WITH MEDALLION II CONTROLLER
Vibration frequency: 5 – 2500 Hz.
Maximum amplitude of displacement: 50 mm.
Maximum force: 40 kN.
Maximum acceleration: for sinusoidal vibrations: 500 m/s², for random (rms) vibrations: 140 m/s², for impacts: 800 m/s².

ENVIRONMENTAL CHAMBER (FOR TESTING VIBRATIONS AT TEMPERATURES) CLIMATS 1200 H 70/5 TYPE WITH SPIRALE 3 CONTROLLER
Workspace dimensions: 1000 x 1100 x 1100 mm (1200 l).
Temperature range: -70°C ÷ +180°C.
Speed of temperature change: 5°C/min.
Humidity range: 20% ÷ 95%.

THERMOBAROCHAMBER CLIMAS 1000 FCV 70/1 TYPE WITH SPIRALE VS CONTROLLER
Workspace dimensions: 1000 x 1000 x 1000 mm (1000 l).
Temperature range: -70°C ÷ +180°C.
Pressure range: from atmospheric to 10 hPa without temperature control, from atmospheric to 50 hPa with temperature control, from atmospheric to 1070 hPa.

ENVIRONMENTAL CHAMBER CLIMATS 4000 H 70/4G WITH SPIRALE 3 CONTROLLER
Workspace dimensions: 2000 x 1900 x 1060 mm (4000 l).
Temperature range: -70°C ÷ +180°C.
Humidity range: 20% ÷ 95%.

SALT SPRAY TEST CHAMBER SF/CCT/VH TYPE WITH EUROTHERM CONTROLLER
Workspace dimensions: 850 x 2000 x 1000 mm (1700 l).
Temperature range: from ambient temperature to +60°C (with humidity) and up to +70°C (without humidity).
Tests according to standards: MIL STD-810E, ISO 6270-2, DIN 50.02, ASTM 13117.
Humidity range: 50% to 95% at 20°C, 30% to 95% at 30°C, 15% to 95% at 60°C.

RAIN TEST CHAMBER SWT 600/800 TYPE WITH SIMPATI CONTROLLER
Workspace dimensions: 1810 x 1800 x 1800 mm (5800 l).
Rotary table diameter: 600 mm.
Possible testing according to: IPX1, IPX2, IPX3, IPX4, IPX5, IPX6 and IPX6K.

SUNEVENT SUN/1000 SOLAR SIMULATION CHAMBER WITH SIMPATI CONTROLLER
Workspace dimensions: 1000 x 1000 x 1000 mm (1000 l).
Irradiation module: Metal halide lamp: 2500 W.
Irradiation intensity: 400-1125 W/m².
Light range: 280-3000 nm.

DUST CHAMBER ST 2000U WITH SIMPATI CONTROLLER
Workspace dimensions: 1000 x 1900 x 950 mm (1800 l).
Dust capacity: 5 kg of dry talcum dust.
Test temperature up to 55°C and according to DIN EN 60529.

RAPID DECOMPRESSION STATION
Dimensions of the chamber in which the test object is placed: 770 x 800 x 800 mm (490 l).
Pressure changes from a value of 746.7 hPa to a pressure between 467 and 90 hPa. Pressure change time not more than 15 ms.

Operational Capacity

Tests of resistance and strength to sinusoidal and random vibrations.
Mechanical impacts resistance and strength tests.
Vibration resistance and strength tests in combination with temperature and/or relative humidity.
Low and high temperature resistance tests.
Tests of resistance to temperature cycling.
Resistance to changes in temperature and atmospheric pressure testing.
Resistance to condensation deposits (frost and dew) testing.
Tests of resistance to increased humidity.
Dust resistance testing.
Corrosion resistance test (salt spray).
Precipitation resistance tests.
Solar radiation resistance tests.

Contact Information

Łukasiewicz Research Network – Institute of Aviation
al. Krakowska 110/114
02-256 Warsaw, Poland
central: (+48) 22 846 00 11
fax: (+48) 22 846 44 32
e-mail: ilot[at]ilot.lukasiewicz.gov.pl

KRS 0000862006, NIP 1070046338, PL 1070046338, Regon: 387193275
Bank PKO SA
90 1240 6247 1111 0000 4977 2760

Directions to the bus stop “Instytut Lotnictwa”
by tram: 7, 9, 15
by bus: 141, 154, 317, N38, N88

Warsaw (Poland)
EREA